¡¡¡¡¡¡¡¡¡¡urrent Location: Products

Class£ºinstrument <<oscliloscope [Close]
CRT Digital Readout Oscilloscope

YB4365 / YB4365L
Main Characteristics:

1. Screen displays setting state, and many parameters can be displayed on the screen in form of character
2. Having cursor caliper lines, it can measure parameters such as ¡÷V, ¡÷T and 1/¡÷T between cursor lines
3. Can automatically set optimal scanning speed, and follow the scanning speed value set automatically by input signal
4. Adopt advanced surface sticking and decorating technique
5. Adoption of advanced switching power supply technology insures the normal application of the instrument between 90-260V

hspace=0

Main Technical Indexes:


Product Name
CTR Digital Readout Oscilloscope
Dimension and Weight
130¡Á280¡Á370 (Height¡ÁWidth¡ÁDepth), about 6kg
Power Supply
AC£º220V¡À10%
Main Technical Indexes
1. Band width: DC¡«100MHz(-3db)/DC¡«60MHz(-3db)
2. Y axis deflection coefficient: 2mV/div-5V/div, step according to 1-2-5, 11 grades, ¡À5%
3. Response of frequency band: 5mV/div: DC-100MHz -3dB/5mV/div: DC-60MHz -3dB
4. Response of frequency band: 2mV/div: DC-20MHz -3dB
5. Rise time: 3.5ns/6ns
6. Max safe input voltage: 400V(DC+ACpeak)¡Ü1KHz
7.Scan fraction: main scanning A: 0.5s/div-50ns/div, 1-2-5 scale, 22 grades, 5%/0.5s/div0.1us/div, 1-2-5 scale, 21 grades, ¡À5%
8. Scan fraction: delayed scanning B: 50ms/div-50ns/div, 1-2-5 scale, 19 grades, delayed scanning5%/50ms/div-0.1us/div, 1-2-5 scale, 18 grades, ¡À5%
9. Scanning linearity error: 5%
10. Post-expansion linearity error: 15%
11. Frequency response: DC-2MHz-3dB
12. Internal trigger source selection: CH1 or CH2
13. Cursor readout: voltage difference DV: 4 digits/voltage difference DV: two horizontal cursor lines (V), effective range: 3div
14. Brightness-adjusting polarity: negative level highlight 15. Brightness-adjusting sensitivity: TTL level
16. Brightness-adjusting range: DC-5MHz
17. Wave form: square wave
18. Range: 0.5Vp-p¡À2%
19. Frequency: 1KHz¡À10%

YB4345 / YB4325
Main Characteristics:

1. Sensitivity is high, max deflection coefficient is 1mV/div
2. Damping and scanning switches cancel the traditional mechanical switches but adopt digital pulse switches
3. Seven kinds of cursor digital readout functions can be provided on screen
4. Adjusting makes various complex waveform synchronization more stable
5. Have relevant functions of general oscilloscope at the same time

hspace=0

Main Technical Indexes:

Product Name
CTR Digital Readout Oscilloscope
Dimension and Weight
150¡Á310¡Á440 (Height¡ÁWidth¡ÁDepth), 8kg
Power Supply
  AC£º220V¡À10%
Main Technical Indexes
1. Band width: DC¡«40MHz(-3db)/DC¡«20MHz(-3db)
2. Y axis deflection coefficient: 1mV/div-5V/div, 1-2-5 scale, 12 grades, error is ¡À5% (1mV-2mV ¡À 8%)
3. Rise time: 5mV-5V/div, about 8.8ns; 1mV-2mV/div, about23ns/5mV-5V/div, about 17.5ns and 1mV-2mV/div, about 35ns
4. Max output voltage: 400V(DC+ACpeak)¡Ü1KHz
5. Vertical display mode: A
6. Triggering source: CH1, CH2, power supply and external connection
7. Triggering mode: automation, normal stage and single time
8. Level locking or alternant triggering: 50Hz-40MHz 2div outside 0.25V/0Hz-20MHz 2div outside 0.25V
9. Threshold value: TTL level (negative level highlight)
10. Cursor measurement function: ¡÷V, ¡÷V%, ¡÷VdB, ¡÷T, 1/¡÷T, DUTY and PHASE
11. Panel setting display: V/DIV, vertical mode, reversed phase, alternation/intermittence, non standard, addition (subtraction), ¡Á10 expansion, rapier (¡Á1¡Á10), X-Y, AT/D and TV-V/H
12. Wave form: square wave
13. Range: 2Vp-p¡À2%
14. Frequency: 1KHz¡À2%

EMAIL£ºytek@yangtek.com¡¡WEBSITE£ºwww.yangtek.com Enter