Dural Trace Generalized Oscilloscope

YB4360 / YB4340
Main Characteristics:

1. Sensitivity is high, max deflection factor is 1mV/div
2. High scale brightness is convenient for illumination in the evening
3. With alternate expansion, normal (¡Á1) and expanded wave form can be displayed at the same time
4. INT, thus stable triggering is achieved needless of switching CH1 and CH2 option switches
5. With TV synchronization, that select new TV trigger circuit can display stable signals of TV-H and TV-V
6. With automatic focus, focus level can be corrected automatically during measuring
7. With trigger locking, trigger circuit is in full-automatic synchronized condition, so manpower is not need to trigger level

hspace=0

Main Technical Indexes:


Product Name
Dural Trace Generalized Oscilloscope
Dimension and Weight
132¡Á321¡Á376 (Height¡ÁWidth¡ÁDepth), 7.2kg
Power Supply
 AC£º220V¡À10% 
Main Technical Indexes
1. Band width: DC¡«60MHz(-3db)/DC¡«40MHz(-3db)
2. Y axis deflection coefficient: 5mV/div-5V/div, step according 1-2-5, 10 grade (range) (1mV/diV-1V/div in ¡Á5MAG)
3. Rise time: about 6ns/¡Ü8.8ns
4. Max input voltage: 300V(DC+AC peak value), rapier: 400V(DC+AC peak value)
5. Scanning mode: ¡Á1, ¡Á10; ¡Á1 and ¡Á10 alternation/ ¡Á1, ¡Á5, ¡Á1 and ¡Á5 alternation
6. Scanning time factor: 0.1us/div-0.2s/div ¡À5%, step according to 1-2-5, 20 grades
7. Triggering source: INT, CH2, power supply and external connection
8. Triggering mode: automatic, normal, TV-V and TV-H
9. X-Y working mode: CH1 is X axis and CH2 is Y axis under working mode of X-Y
10. Max input voltage of Z axis: 30V (DC+AC peak value), max frequency: ¡Ü1KHz
11. Output level: 0.5V(¡À2%)
12. Frequency: 1KHz¡À2%


YB4360 / YB4340
Main Characteristics:

1. Sensitivity is high, max deflection factor is 1mV/div
2. High scale brightness is convenient for illumination in the evening
3. With alternate expansion, normal (¡Á1) and expanded wave form can be displayed at the same time
4. INT, thus stable triggering is achieved needless of switching CH1 and CH2 option switches
5. With TV synchronization, that select new TV trigger circuit can display stable signals of TV-H and TV-V
6. With automatic focus, focus level can be corrected automatically during measuring
7. With trigger locking, trigger circuit is in full-automatic synchronized condition, so manpower is not need to trigger level
8. Element test function (YB4320B)
9. Product with high and new-technology (YB4320A) and high price/performance ratio (YB4320B)
hspace=0

Main Technical Indexes:


Product Name
Dural Trace Generalized Oscilloscope
Dimension and Weight
132¡Á321¡Á376 (Height¡ÁWidth¡ÁDepth), 7.2kg
Power Supply
 AC£º220V¡À10% 
Main Technical Indexes

1. Band width: DC¡«20MHz(-3db)/DC¡«25MHz(-3db)
2. Y axis deflection coefficient: 5mV/div-5V/div, step according 1-2-5 , 10 grade (range) (1mV/diV-1V/div in ¡Á5MAG)
3. Rise time: ¡Ü17.5ns
4. Max input voltage: 300V(DC+AC peak value), rapier: 400V(DC+AC peak value)
5. Scanning mode: ¡Á1, ¡Á5, ¡Á1 and ¡Á5 alternation
6. Scanning time factor: 0.1us/div-0.2s/div ¡À5%, step according to 1-2-5 , 20 grades
7. Triggering source: Y1, Y2, alternation, power supply and external connection
8. Triggering mode: automatic, normal, TV-V and TV-H
9. X-Y working mode: CH1 is X axis and CH2 is Y axis under working mode of X-Y
10. Max input voltage of Z axis: 30V (DC+AC peak value), max frequency: ¡Ü1KHz
11. Output level: 0.5V(¡À2%)
12. Frequency: 1KHz¡À2%

YB4328 / YB4324
Main Characteristics:

1. Sensitivity can be increased to 1mV/div through expansion function
2. Scanning system adopts full band triggering mode automatic scanning circuit
3. Flexible and convenient triggering mode can provide to respectively select function to trigger some channel signal or external input signal
4. With alternate triggering function, it can be used to observe advantages of irrelevant signals in two ways at the same time
5. Setting triggering input terminal, it can output CH1 and CH2 signals along with trigger port, and is used for outer frequency

hspace=0

Main Technical Indexes:


Product Name
Dural Trace Generalized Oscilloscope
Dimension and Weight
320¡Á130¡Á400 (Height¡ÁWidth¡ÁDepth), 7.2kg
Power Supply
 AC£º220V¡À10% 
Main Technical Indexes
1. Band width: DC¡«20MHz(-3db)
2. Y axis deflection coefficient: 5mV/div-10V/div
3. Rise time: ¡Ü18ns, and ¡Ü70ns/:17.5ns after expansion
4. Max input voltage: 400V(DC+ACp-p)
5. Scanning mode: automation, triggering, locking and single time
6. Scanning time factor: 0.1¦Ìs/div¡«0.2s/div, step according to 1-2-5, 20 grades, error is ¡À5£¥
7. Triggering source: Y1, Y2, alternation, power supply and external connection
8. Min sync level: triggering: 5Hz¡«20MHz/10Hz¡«20MHz, inside: ldiv, outside: 0.2Vp-p, TV inside: 2div, outside: 0.3Vp-p, inside is 2div when triggering locking (20Hz¡«10MHz)
9. Frequency response: AC: 10Hz¡«lMHz -3dB, DC: 0¡«lMHz -3dB
10. Max input voltage of Z axis: 50V(DC+ACp-p)
11. Min output level: TTL level
12. Afterglow: medium
13. Wave form: square wave
14. Range: 0.5¡À2%Vp-p
15. Frequency: 1KHz¡À2%



YB4330
Main Characteristics:

1. Sensitivity can be increased to 1mV/div through expansion function
2. Scanning system adopts full band triggering mode automatic scanning circuit
3. Flexible and convenient triggering mode can provide to respectively select function to trigger some channel signal or external input signal
4. With alternate triggering function, it can be used to observe advantages of irrelevant signals in two ways at the same time
5. Setting triggering input terminal, it can output CH1 and CH2 signals along with trigger port, and is used for outer frequency meter.



hspace=0

Main Technical Indexes:


Product Name
Dural Trace Generalized Oscilloscope
Dimension and Weight
320¡Á130¡Á400 (Height¡ÁWidth¡ÁDepth), 7.2kg
Power Supply
 AC£º220V¡À10% 
Main Technical Indexes
1. Band width: DC¡«30MHz(-3db)
2. Y axis deflection coefficient: 1mV/div-10V/div, step according to 1-2-5, 10 grades (range) (1mV/diV-1V/div in ¡Á5MAG)
3. Rise time: ¡Ü17.5ns
4. Max input voltage: 300V(DC+AC peak value), rapier: 400V(DC+AC peak value)
5. Scanning mode: ¡Á1, ¡Á5, ¡Á1 and ¡Á5 alternation
6. Scanning time factor: 0.1us/div-0.2s/div ¡À5%, step according to 1-2-5, 20 grades
7. Triggering source: Y1, Y2, alternation, power supply and external connection
8. Triggering mode: automatic, normal, TV-V, TV-H
9. X-Y working mode: CH1 is X axis and CH2 is Y axis under working mode of X-Y
10. Max input voltage of Z axis: 30V (DC+AC peak value), max frequency: ¡Ü1KHz
11. Output level:0.5V(¡À2%)
12. Frequency: 1KHz¡À2%